Detection of fungal infection and Ochratoxin A contamination in stored wheat using near-infrared hyperspectral imaging

Citation

Senthilkumar, T., Jayas, D.S., White, N.D.G., Fields, P.G., Gräfenhan, T., 2016. Detection of fungal infection and Ochratoxin A contamination in stored wheat using near-infrared hyperspectral imaging. Journal of Stored Products Research 65, 30-39.

Plain language summary

A study was done to detect two fungi found on grain; Aspergillus glaucus, and Penicillium spp., and the myctoxin, Ochratoxin A in stored wheat using a Near-Infrared (NIR) Hyperspectral Imaging system. Fungal-infected samples were imaged every two weeks. Analysis showed that 3 wavelengths, 1280, 1300, and 1350 nm, were identified as useful in distinguishing the samples for level of infection. Using statistical methods we were able to differentiated healthy kernels from fungal-infected kernels with a classification accuracy of more than 90%. The Ochratoxin A contaminated samples had a unique significant wavelength at 1480 nm in addition to the two significant wavelengths corresponding to fungal infection. The peak at 1480 nm was identified only in the Ochratoxin A contaminated samples. The Ochratoxin A contaminated samples can be detected with 100% classification accuracy using NIR hyperspectral imaging system. The NIR hyperspectral system can differentiate between different fungal infection stages and different levels of Ochratoxin A contamination in stored wheat.

Abstract

© 2015.A study was done to detect Aspergillus glaucus, and Penicillium spp., infection and Ochratoxin A contamination in stored wheat using a Near-Infrared (NIR) Hyperspectral Imaging system. Fungal-infected samples were imaged every two weeks, and the three dimensional hypercubes obtained from image data were transformed into two dimensional data. Principal component analysis was applied to the two dimensional data and based on the highest factor loadings, 1280, 1300, and 1350 nm were identified as significant wavelengths. Six statistical features and ten histogram features corresponding to the significant wavelengths were extracted and subjected to linear, quadratic and Mahalanobis discriminant classifiers. All the three classifiers differentiated healthy kernels from fungal-infected kernels with a classification accuracy of more than 90%. The quadratic discriminant classifier provided classification accuracy higher than the linear and Mahalanobis classifiers for pair-wise, two-way and six-way classification models. The Ochratoxin A contaminated samples had a unique significant wavelength at 1480 nm in addition to the two significant wavelengths corresponding to fungal infection. The peak at 1480 nm was identified only in the Ochratoxin A contaminated samples. The Ochratoxin A contaminated samples can be detected with 100% classification accuracy using NIR hyperspectral imaging system. The NIR hyperspectral system can differentiate between different fungal infection stages and different levels of Ochratoxin A contamination in stored wheat.

Publication date

2016-01-01

Author profiles